Uhandisi Solutions
Uhandisi Solutions (Pty) Ltd portfolio ranges from consulting studies, IT services to EPCM (Engineering, Procurement Assistance and Construction).

Get Professional Advice from Professional Engineers
INTEGRITY
TRUST
PROFESSIONAL TEAM
QUALITY
Have A Project
We Can Help With?
Specialists In
Electrical, Project Management & IT Solutions
Electrical Planning Studies
Field Services
Power System Specialist
Industrial Automation & Control
Renewable Energy
Electrical Distribution EPCM
SHEQ & Fire Systems Management Services
Electrical Distribution EPCM
Working at the highest level
with our clients

Business Problem:
Engineerex was contracted by Alfred Duma Local Municipality to provide consulting services for the design of bulk electrical services(Medium and Low Voltage for a new mixed use development site.
Solution:
Uhandisi Solutions did concept, preliminary and detailed designs for medium and low voltage bulk services. We also did the full pricing of the design and prepared the tender documentation for council approval.
Business Value:
The medium and low voltage electrical bulk services design and tender document was accepted and signed off to go out on tender.

Business Problem:
Shuma’s client, the department of health in Mpumalanga had technical challenges in their Waste Water Treatment Plants due to lack of As-Built drawings.
Solution:
Uhandisi Solutions conducted site visits in their plants to collect data. We then analysed the data (Pictures and drawings) to develop As-built drawings and provide technical reports.
Business Value:
The As-built drawings assisted Shuma’s client to comply with relevant regulatory standards relating to the operations of Waste Water Treatment Plants.

Business Problem:
Congo Energy's client, Congo Equipment SARL, had a power station built at its new Luano site in Lubumbashi with generators that should synchronize and share the load according to energy demand. Congo Energy had been entrusted with the commissioning and programming task to synchronize three generators through command / control cabinets equipped with Deep Sea PLC controllers.
Solution:
Uhandisi Solutions carried out, under Congo Energy, all on-site acceptance tests and the necessary modifications before programming the Deep See PLC controllers. We then produced detailed drawings of the system as built.
Business Value:
The power station has been put into operation and functioning automatically with synchronization / loads sharing according to the energy demand. This automation has enabled Congo Equipment to save on fuel consumption and maintenance.

Business Problem:
Uhandisi Solutions had been asked to make the electrical connections for the assembly of various process control components of their new DynoPro2 test bench, at their new site in Luano in Lubumbashi.
Solution:
Uhandisi Solutions, carried out site visits to the facilities to collect data. We then analyzed the data, but especially the detailed technical drawings provided by the manufacturer. This allowed us to make all the necessary connections.
Business Value:
The interconnections between the different components allowed the commissioning and online testing of the test bench by the manufacturer, before handing it over to Congo Equipment. With this test bench, our customer is able to test all kinds of large diesel and electric motors for the whole region.

Business Problem:
The University of Limpopo has got aging electrical infrastructure which has reached its lifespan. As a result, the university would experience breakdowns and spares are nowhere to be found as they are absolute.
Solution:
Refurbishment of 11kV oil switchgear to 11kV SF6 Schneider RM6 at substations A6 – I Block, M1 – Library and A2 – Q Block. This solution may also be referred to as modernization of electrical infrastructure.
Business Value:
Network reliability, safety and continuity of electrical supply.


Business Problem:
The University of Limpopo’s Gate 2 Generator plant would start and breakdown due to lack regular testing, monitoring and maintenance. This plant is a critical asset to the university as it provides standby power supply to the entire university community.
Solution:
Uhandisi Solutions provides a 24hrs standby, weekly onload testing and service maintenance to this 4.8MW Emergency Standby Generator Plant.
Business Value:
Continuity of supply during planned and unplanned power outages.


Business Problem:
The University of Limpopo’s medium voltage infrastructure has reached its life span and spares have become absolute. The university’s electrical distribution network is a critical asset for their operations.
Solution:
Uhandisi Solutions supplied, installed, tested and commissioned 3x315kVA Mini-substation which are modern, SF6 gas insulated and spare parts are available and easily accessible.
Business Value:
Reliability, safety and continuity of supply.


Business Problem:
Uhandisi Solutions was appointed for the supply, installation, test and commissioning of bulk electrical infrastructure at Kaalfontein and Matholesville.
Solution:
Supplied, installed and commissioned 2xMinisubstations, 2 x LV Kiosk and Guard House DB together with well over 30 LED Streetlights for both Matholesville and Kaalfontein sites.
Business Value:
New bulk electrical installation as per design specification.


Business Problem:
Ubank is looking at a complete replacement of old standby diesel generators at their branches nonetheless the bank is not certain about the sizes of such generators.
Solution:
Uhandisi Solutions deployed their Fluke 1736 Power Logger to capture the power consumption at each branch and delivered a report to confirm the standby diesel generator size to be used for replacement of old generator sets.
Business Value:
Reliable power consumption data and PrEng signoff for final report.


Business Problem:
Cresta Mall sought to conduct their yearly 11kV switchgear maintenance and Battery Charger batteries replacement as part of preventative maintenance and best engineering practice.
Solution:
Uhandisi Solutions arranged a shutdown with the client to conduct circuit breaker maintenance and secondary injection testing.
Business Value:
Complete preventative maintenance and adherence to best engineering practice.


Business Problem:
The University of Limpopo’s 11kV main substation should be tested for yearly maintenance of switchgear.
Solution:
Uhandisi Solutions serviced all the main substation 11kV circuit breakers and performed secondary injection testing for the relays.
Business Value:
Reliability and continuity of supply.

VOA Head Quarters, 323 Lynnwood Road,
Menlo Park, Pretoria
Amy Park, Office No. 2, 128 Marshall Street,
Polokwane
Phone: 012 880 2907 | 015 880 0513
Having trouble? Find the answer to your query here. Don’t hesitate to contact us!